WESERGATE NAC / DOCUMENTATION

1,000-endpoint pilot

Scope The 1,000-endpoint SKU is a licensing tier and engineering load-test target , not a statement that this hardware or release has achieved 1,000 concurrent EAP authentications. Validate against the actual supported s

v0.14.3Pre-production · v0.14.3
v0.14.3 documentation draft: technical, legal and commercial reviews are still pending.

Scope

The 1,000-endpoint SKU is a licensing tier and engineering load-test target, not a statement that this hardware or release has achieved 1,000 concurrent EAP authentications. Validate against the actual supported switch/identity mix before any SLA.

Preparations

  1. Confirm Linux host, physical NICs, switch management network, VLAN design, NTP, DNS, LDAPS trust, RADIUS server certificates and Keycloak/SMTP reachability.
  2. Start with one noncritical switch and endpoint. Establish per-port authentication, accounting, access policy, identity provenance and failure rollback.
  3. Inventory 100 unique MACs first; measure discovery duration, evidence inserts, auth-event rate, DB size, CPU, memory and slow SQL.
  4. Increase in staged groups (100 → 250 → 500 → 750 → 1,000) with documented pause/review after each. Do NOT generate mass authentication traffic against production network hardware without approval.
  5. Record P50/P95/P99 API response time, discovery lag, event ingest rate, DB write throughput, PostgreSQL I/O and memory, certificate validity, backups and restore times.
  6. Exercise 24–72-hour endurance at representative real-world traffic rates. Test switch outages, AD/RADIUS unavailability, DNS failures, email outages, restart and upgrade/restore.

Suggested acceptance thresholds (to be approved by customer)

The project does not include published measured thresholds. Agree explicit service SLOs, RADIUS accept/reject latency, acceptable inventory freshness, backup RPO/RTO and approved event retention before certification. Technical test instrumentation, realistic workload and switch compatibility are necessary.

Constraints

One appliance container includes Caddy, API worker, background worker and PostgreSQL. There is no validated active/active cluster. Evidence and event counts can be far larger than 1,000. Indexes and opt-in retention help manage growth, but are not a replacement for profiling or partitioning. License endpoint count is MAC-based Device inventory rows, not concurrent sessions.

Original English reference: en/docs/getting-started/scalability-1000.mdRead documentation
Pre-production · v0.14.3

Not a certified production NAC. Physical switch/RADIUS enforcement and 1,000-device traffic remain unverified.

WeserCode One now provides customer accounts, support tickets and verified commercial records. Automated checkout and signed WeserGate license issuance are not connected.

Open customer portal Product overview