EN Product and technical documentation are preserved in the packet’s original English. WeserCode navigation and controls follow your selected site language.
Documentation · VERSION 0.9.0

Windows native storage

Use the local Windows connector on the Windows server that owns the approved share/folder. AccessScope checks the share-to-local-folder relationship and co

Editorial review
i
Source-aligned documentation preview

This v0.9.0 page is preserved from the supplied documentation packet and remains marked for editorial approval. Product behavior and limitations are stated as documented; this preview is not a claim of external acceptance or certification.

Use the local Windows connector on the Windows server that owns the approved share/folder. AccessScope checks the share-to-local-folder relationship and collects native directory security metadata.

Configure

Choose Windows server (local collector), an exact UNC share root and its Local Windows share folder on a local drive. For example, a share root \fileserver\Finance can map to D:\Shares\Finance when that is the real share mapping on the collector.

Set a descriptive collector identity label, actual read credential where supported, directory association and explicit application profile scopes. A label is not a Windows logon.

The frozen service defaults to LocalService. Its token will not automatically carry your interactive user's domain credentials or filesystem privileges. Delegate the supported read identity deliberately; use a domain service account only through an approved operating-system service configuration.

Read and explain

Inspect one folder. Review filesystem DACL and available share ACL separately. Ordered ACEs, allow/deny type, masks and inheritance flags are retained. Unsupported callbacks/claims/runtime token conditions remain limitations.

Native collection rejects reparse points and validates resolved paths inside the approved mapping. Missing read access is an error, not an empty ACL.

Governed local changes

The supported Windows DACL workflow targets one directory and requires the deployment/source gates, a separate write credential, read evidence, scoped change roles, independent approval, MFA and a fresh confirmation. It does not expose share ACL rewrites, owner changes, recursive propagation or arbitrary inherited ACE editing.

A remote collector provides read transport; it does not forward central write execution.

Acceptance

Test read-only metadata and native access semantics on the intended Windows Server version. The Windows/native access-check tests were not executed in the Linux build environment. A graph and DACL calculation still do not reconstruct every privilege, session, central policy or logon restriction.

See governed changes and permission evidence.

DOCUMENT CONTROL

Product baseline v0.9.0 · State schema 8 · Content reviewed 2026-11-06. This website rendering preserves the source packet's qualifiers, compatibility boundaries and acceptance status.

WESERCODE ONE / CUSTOMER PORTAL

One customer account for every product.

Support tickets, order inquiries, and verified license and subscription records in one secure workspace.

Open customer portal ↗
BUILT BY WESERCODE · BREMEN

Make access easier to understand.

Discuss an evaluation, deployment question or the product roadmap with WeserCode.

Talk to WeserCode ↗